If breece explorer raise in Displays in queue. the number in the reed box is very high


C:\Program Files (x86)\Delfi Technologies\Breece Server\Logs\Firmware 

see the file Display to update. see if the last displays is in the following file

go to

C:\ProgramData\Bounce\BounceComms

open file engineeringAPI-ERRORS


se if this is the error

ERROR -> BounceEngineeringAPITestApp-1: InsertEngineeringRequest() -> FAILED to queue job for epop KB10079364B. Either the epop is not in the system or it has not passed network configuration

then do following.


Then the displays is deleted but the system gave it a firmware update at the same time.


Open SQL management

servername .\SQLbounce/breece/tables/audit_display_firmware_update_tbl



select * from audit_display_firmware_update_tbl where FirmwareJobCompleted is null



if you what to delete jobs in queue

 

Delete * from audit_display_firmware_update_tbl where FirmwareJobCompleted is null


then the queued should be gone and see if the line get bigger again. if not case closed